Peruvian Energy Company Optimizes Communications Network with Secure and Reliable Wireless M2M Solutions
Customer Company Size
Large Corporate
Region
- America
Country
- Peru
Product
- FreeWave FGR09CSU
- FreeWave M2M Communication Devices
Tech Stack
- SCADA System
- Wireless M2M Communication
Implementation Scale
- Pilot projects
Impact Metrics
- Cost Savings
- Customer Satisfaction
- Productivity Improvements
Technology Category
- Functional Applications - Remote Monitoring & Control Systems
- Networks & Connectivity - Wireless Local Area Network
Applicable Industries
- Oil & Gas
Applicable Functions
- Field Services
- Maintenance
Use Cases
- Machine Condition Monitoring
- Predictive Maintenance
- Remote Asset Management
Services
- System Integration
About The Customer
China National Petroleum Company (CNPC) is the sixth largest energy company in the world. It has been in business for more than 55 years, with nearly 75,000 employees worldwide and presence in 28 countries. In Peru, CNPC began its operations in 1996 and holds stakes in exploratory assets in Northern and Southern Peru in four different basins: Marañon, Huallaga, Madre de Dios, and Ucayali.
The Challenge
In late 2009, CNPC started a pilot test using a wireless M2M communication solution made by a competitor of FreeWave Technologies. CNPC has numerous oil fields in Northern Peru (El Alto), and it had plans to test the new equipment in a coastal environment near the ocean in Piura, Peru. Close to the equator, the average temperature there is 35 degrees Celsius (95 degrees Fahrenheit), and this particular zone has small rivers and large amounts of rain in the summer. The goal was to have several test sites reporting to a gateway and then into a SCADA system to monitor several pumping devices and equipment including: Pump of Controller (POC), Pump Cavity Progressive (PCP), Balance Oil Recovery System (BORS) and plunger lift. For the pilot, distances between links were not long. However, the challenge was to communicate to sites that were located in depressions, canyons or small streams and did not have clear line-of-site (LOS). Engineers at CNPC attempted to get the pilot M2M network working for several weeks, but the competing communication solutions caused a lot of ambient noise and failed to establish reliable or consistent links. Without working links, the pilot would be a failure.
The Solution
In order to be successful, the engineering team looked to FreeWave Technologies to help reconfigure the competing solutions to ensure they had adequate separation between antennas on the tower. For the links that did not have LOS, they used FreeWave’s FGR09CSUs in slave/repeater mode. The FreeWave wireless M2M communication devices demonstrated better performance and versatility in the applications with no LOS. Within 30 minutes, the new M2M communication devices were installed. Although slightly more time was dedicated toward the selection of the repeater sites, the entire system seamlessly integrated into their SCADA system. Almost immediately upon deployment, FreeWave was able to establish a link, which was something CNPC had not accomplished with the competing solutions.
Operational Impact
Quantitative Benefit
Case Study missing?
Start adding your own!
Register with your work email and create a new case study profile for your business.
Related Case Studies.
Case Study
Taking Oil and Gas Exploration to the Next Level
DownUnder GeoSolutions (DUG) wanted to increase computing performance by 5 to 10 times to improve seismic processing. The solution must build on current architecture software investments without sacrificing existing software and scale computing without scaling IT infrastructure costs.
Case Study
Remote Wellhead Monitoring
Each wellhead was equipped with various sensors and meters that needed to be monitored and controlled from a central HMI, often miles away from the assets in the field. Redundant solar and wind generators were installed at each wellhead to support the electrical needs of the pumpstations, temperature meters, cameras, and cellular modules. In addition to asset management and remote control capabilities, data logging for remote surveillance and alarm notifications was a key demand from the customer. Terra Ferma’s solution needed to be power efficient, reliable, and capable of supporting high-bandwidth data-feeds. They needed a multi-link cellular connection to a central server that sustained reliable and redundant monitoring and control of flow meters, temperature sensors, power supply, and event-logging; including video and image files. This open-standard network needed to interface with the existing SCADA and proprietary network management software.
Case Study
Refinery Saves Over $700,000 with Smart Wireless
One of the largest petroleum refineries in the world is equipped to refine various types of crude oil and manufacture various grades of fuel from motor gasoline to Aviation Turbine Fuel. Due to wear and tear, eight hydrogen valves in each refinery were leaking, and each cost $1800 per ton of hydrogen vented. The plant also had leakage on nearly 30 flare control hydrocarbon valves. The refinery wanted a continuous, online monitoring system that could catch leaks early, minimize hydrogen and hydrocarbon production losses, and improve safety for maintenance.