ICONICS > Case Studies > Customer Success Story - SC «ATS» Company, Ltd.

Customer Success Story - SC «ATS» Company, Ltd.

ICONICS Logo
Company Size
11-200
Region
  • Europe
Country
  • Russia
Product
  • ICONICS GENESIS32™
  • TrendWorX™32
  • DataWorX™32
Tech Stack
  • OPC servers
  • SQL servers
  • Microsoft Office
Implementation Scale
  • Enterprise-wide Deployment
Impact Metrics
  • Cost Savings
  • Productivity Improvements
Technology Category
  • Analytics & Modeling - Real Time Analytics
  • Application Infrastructure & Middleware - Data Exchange & Integration
Applicable Industries
  • Oil & Gas
Applicable Functions
  • Process Manufacturing
Use Cases
  • Predictive Maintenance
  • Process Control & Optimization
Services
  • System Integration
About The Customer
SC «ATS» specializes in the design, creation, introduction and tracking of automation systems in the Russian petroleum and natural gas industries. SC «ATS» acts specifically as a system integrator, providing design for, delivery of, and service to gas and oil-producing industry control systems. The company works with multiple plants in the Russian oil and gas industry and has been involved in providing control systems in three locations: OAO Surgutneftegaz, NK Rosneft, and TNK BP (Tumenneftegaz).
The Challenge
SC «ATS» works with multiple plants in the Russian oil and gas industry. The company was involved in providing control systems in three locations: OAO Surgutneftegaz, with more than 40 objects; NK Rosneft, with more than 20 objects; and TNK BP (Tumenneftegaz), with more than 10 objects. The multiple objects to control at each plant make use of a wide variety of technologies, including radio, GSM/GPRS, Wi-Fi and Ethernet connectivity. In total, there are approximately 16 distributed control stations on area objects and about 118 on telemechanical systems. The types of connected devices include multiple controllers, flowmeters and heater controllers from B&R and Siemens, which are connected to ICONICS HMI/ SCADA interface via OPC servers.
The Solution
SC «ATS» has selected ICONICS GENESIS32™ OPC Web-enabled HMI/SCADA suite; including the TrendWorX™32 enterprise-wide data collection, logging, charting, reporting and analysis component and the DataWorX™32 OPC data aggregation, bridging, redundancy and tunneling add-on; for its suggested industrial automation software solution. The OPC servers themselves are used primarily for data collection, while OPC loggers are for reporting/logging and SQL servers are used for data storage. The total number of I/O points ranges from four on the telemechanical control systems to up to 14,000 on area object points. SC «ATS» uses Microsoft software in its control system solutions, including SQL Server and Microsoft Office (Excel, Access, etc.).
Operational Impact
  • System response to events now occurs in less than a second.
  • Objects are easily visualized in a user-friendly Web interface.
  • The installed system has been deemed easy to expand.
  • Improvements in overall system-level security and in the oil and gas processes themselves.
  • Cut overall development time for SC «ATS»’s control systems, as well as the number of personnel required for system design and maintenance.
Quantitative Benefit
  • Reduced system response time to less than a second.
  • Reduced overall development time for control systems.
  • Reduced number of personnel required for system design and maintenance.

Case Study missing?

Start adding your own!

Register with your work email and create a new case study profile for your business.

Add New Record

Related Case Studies.

Contact us

Let's talk!
* Required
* Required
* Required
* Invalid email address
By submitting this form, you agree that IoT ONE may contact you with insights and marketing messaging.
No thanks, I don't want to receive any marketing emails from IoT ONE.
Submit

Thank you for your message!
We will contact you soon.